Stone Claddin Profiles

Expanded Metals help the formation of joints, protection of corners and resistance against cracks, chips and impact damage.
Calculations are provided by our design office in Stuttgart, Germany.

- For interior applications:
Galvanized Steel according to BS EN 10327 superseded by BS EN 10346:2009, zinc coated on both sides.

- For exterior applications and humid environment:
Austenitic stainless steel according to BS EN 10088- Mat.No.1.4301

Technical Specifications

Metal Beads
Relevant Standards:
- BS EN 13914- 2 : 2005 Design , Preparation and Application of External Rendering and Internal Plastering
- BS EN 13658-1 : 2005 Metal Lath and Beads – Definitions , Requirements and Test Methods , Internal Plastering Supersedes BS 1369-1 :1987 and BS 6452-1 : 1984
- BS EN 13658 – 2 : 2005 Metal Lath and Beads – Definitions , Requirements and Test Methods , External Plastering Supersedes BS 1369-2 :1987 and BS 6452-2 : 1984
- ASTM C841 – Standard Specification for Installation of Interior Lathing and Furring
- ASTM C847 – Standard Specification for Metal Lath
- ASTM C1063 – Standard Specification for Installation of Lathing and Furring for Portland Cement – Based Plaster
- International Building Code , ( IBC ) Chapter 25
- International Residential Code , ( IRC ) Chapter 7

Galvanized Steel:
- BS EN 10346:2009 (formerly BS EN 10142: 1991) coating type: Z180-275 ASTM A 653/A 653M

Stainless Steel:
- BS EN 10088-2:2005 (which was directly equivalent to formerly BS 1449:Part 2:1983 in Grade 304 2B FINISH
- ASTM A240/A240M in Grade 304 2B FINISH

Expanded Metal Lath & Block Work Expanded Mesh

Relevant Standards:
- BS EN 13658-1 & 2:2005 (formerly BS 1369:Part 1:1987)
- ASTM C 847

Galvanized Steel:
- BS EN 10346:2009 (formerly BS EN 10142:1991) coating type: Z180-275
- ASTM A 653/A 653M

Stainless Steel:
- BS EN 10088-2:2005, which was directly equivalent to formerly BS 1449:Part 2:1983 in Grade 304 2B FINISH
- ASTM A240/A240M in Grade 304 2B FINISH

Reiforcement Mesh

Relevant Standards:
- BS EN 845-3:2003
- ASTM A 951/A 951M

Cold drawn steel for concrete/mansonry reinforcement
- BS 4482:2005
- ASTM A 496/A 496M, ASTM A 82/A 82M

Pre galvanized steel wire
- BS EN 10244-2:2001 formerly BS 443
- ASTM A 641/A 641M

Stainless Steel wire
- BS EN 10088-3:2005 (which was direct equivalent to formerly BS 1554:1990) - BS 1449:Part 2:1983 in Grade 304 2B FINISH - ASTM A 1022/A 1022M


PRODUCTS


Angle Bead

Angle beads provide with its solid metal nose a straight corner. Expanded diamond mesh wings allow for keying the plaster right up to the nose of the bead. It is designed to protect the corners.

Plaster Stop Bead

Plaster stop bead provides a straight accurate line, it is used to reinforce the plaster or render on its edge. Plaster stop bead is designed as a universal plaster stop used at wall ends, door and window openings to make a neat, flush frame.

Movement Bead

Movement Beads are used to relieve the stress and strain in large plaster areas of wall and ceiling stucco areas and to allow for movement between adjoining surface finishes.

Architrave Bead With flange

Mainly used for decorative purposes to give a channel gap or a shadow between different walls finishes.

Architrave Bead Without flange

Mainly used for decorative purposes to give a shadow between different walls finishes.

Metal Sheet Lath

Sheet lath is produced as a key for plaster when applied on suspended ceiling and walls. Sheet lath is used for encasing steel column and beams, assisting in the protection from fire.

Rib Lath

Manufactured from Pre-galvanized steel to BSEN 10327. Hy Rib is available using stainless steeI to BSEN 10088-2 type 1 .4301 . The profile of Hy Rib open mesh in combination with its ribs provide an inherently stiff sheet along its length.

Glass Fiber Mesh

Strip Mesh Lathes are used along stress lines where cracking is likely. Strip mesh provides reinforcement to the plaster to prevent crack over joints of different materials.

BR Mesh

Block reinforcement meshes are produced for brick and block work reinforcement. Their primary usage is to prevent cracking. Brick reinforcement meshes increase resistance to tensional stress.

Wall Ties

Wall Ties Quality Product

© 2017 SFSP Lebanon | All rights reserved